5 things about Gas Turbine Inlet Air Cooling (GTIAC) you need to know

 GTIAC is a cost-effective optimised solution.

Today, there are various ways to enhance the power output of gas turbines. The most cost-effective means is Gas Turbine Inlet Air Cooling (GTIAC). This technology can increase a gas turbine generator’s output to produce 30%+ more electricity at a fraction of the cost of a new gas turbine generator.

The most consistently successful method of GTIAC is mechanical cooling. Based on proven water-chiller and heat-exchanger technologies, this method delivers the
cooling capacity, dependably and consistently to obtain optimal output from the gas turbine. Operating the turbine at the relatively constant conditions offered
by mechanical cooling can improve turbine life and lower maintenance costs.

Five important things about Gas Turbine Inlet Air Cooling (GTIAC) you need to know:

1. Selecting intake temperature

For GTIAC, a commonly considered bell mouth intake air temperature is 15oC. This may not be the optimal intake temperature for all GTIAC installations. In locations with high humidity, you need to consider the level of “sensible” cooling that is economically optimal. Otherwise, chiller capacity will be used in condensing the water vapor in the air.

2. Determining design point

When selecting a design point for GTIAC, it is important to remember that relative humidity (RH) and ambient temperature are counter cyclical. The RH at any location drops with an increase in ambient dry bulb temperature and vice versa. If the design set point is selected based on the highest RH and highest dry bulb temperature at a location, it would result in a vastly oversized chilling plant.

3. Choosing chilling coil

Optimal chilling coil design is crucial. If the chilling coil size in the filter house is too small, the chilled water temperature required to achieve the desired inlet air temperature would be low and the chilled water delta T would be small. To produce this chilled water at lower temperature and small delta T, a larger capacity chiller plant is required, with higher than necessary parasitic load.

4. Configuring multiple chillers

Connecting multiple chillers in series counter flow configuration has a significant impact on system efficiency. This type of cascading configuration can reduce
the compressor work needed by each chiller, improving the overall chiller system efficiency by as much as 8%.

5. Designing holistically

In many projects, the scope of supply responsibility for chiller plant and coils lies with separate vendors. This results in a GTIAC system that does not have optimal lifetime performance. It is vital to take a holistic approach to GTIAC system design from the start.

Jaringan listrik lemah Vietnam menghambat kebijakan pembelian listrik yang langsung

Infrastruktur energi yang buruk menghambat integrasi kapasitas baru dari proyek energi terbarukan (EBT).

Penutupan pembangkit listrik batu bara baru di ASEAN pada 2040 mungkin tercapai

Penambahan pembangkit batu bara baru dan retrofit pembangkit yang ada menjadi risiko lebih besar dalam transisi.

ADB menyetujui pinjaman senilai $500 juta untuk mendukung transisi energi Indonesia

Ini bertujuan membangun kerangka kebijakan yang kokoh dalam mendukung peralihan menuju energi bersih.

Avaada meningkatkan beban energi terbarukan untuk penuhi permintaan pusat data India

Perusahaan menargetkan kapasitas energi terbarukan sebesar 30 gigawatt pada 2030.

Asia-Pasifik mungkin tidak mencapai target energi terbarukan

Negara-negara di kawasan itu harus menarik investasi untuk memajukan tujuan energi bersih mereka.

Laba bersih Adaro turun 12% menjadi $880 juta di Semester 1

Pendapatan turun 15% menjadi $2,97 miliar pada periode tersebut.

ACEN dan Barito Renewables bermitra untuk mempercepat energi angin di Indonesia

Kemitraan ini akan dijalankan oleh anak perusahaan mereka.

Malaysia diminta mengintegrasikan jaringan listrik untuk mempercepat pertumbuhan tenaga surya

Pembatasan penetrasi tenaga surya ke jaringan pada 24% dari permintaan puncak dapat menghambat ekspansi.